Categories
internet

Upgrade from Windows 10 1809 to 1909 time and again fails because of Error 0xC1900101 – 0x20017

My spouse’s desktop Windows 10 laptop time and again fails to improve to model 1909 because of error 0xC1900101 – 0x20017. I’ve adopted each instruction I’ve been ready to search out. The one factor I realize is that I’m additionally not able to finish sfc /scannow. It reaches 70% after which offers the message that “Windows Resource Protection may just no longer carry out the asked operation.” I attempted many answers, together with deleting more than a few set up folders, unplugging peripherals and USB gadgets, chkdsk with repair, DISM. I did a startup with all non-windows startups and maximum services and products no longer operating. All answers ended up with the similar error, which happens as rebooting takes position after set up fails.

This error 0xC1900101 – 0x20017, as I realize it, pertains to a driving force drawback. I’ve been not able to resolve which driving force.

The setuperr.log says the next. Perhaps somebody with experience can assist me interpret it.

2019-11-19 23:11:18, Error MOUPG CDlpActionImpl<elegance CDlpErrorImpl<elegance CDlpObjectInternalImpl<elegance CUnknownImpl<elegance IMoSetupDlpAction> > > >::Suspend(1253): Result = 0xC1800104[gle=0x00000002]

2019-11-19 23:11:18, Error MOUPG CDlpTask::CheckUserInterruptEx(3060): Result = 0x800704D3

2019-11-19 23:11:18, Error MOUPG CDlpTask::CheckUserInterrupt(3112): Result = 0x800704D3

2019-11-19 23:11:18, Error MOUPG CSetupManager::ExecuteInstallMode(794): Result = 0x800705BB

2019-11-19 23:11:18, Error MOUPG CSetupManager::ExecuteDownlevelMode(392): Result = 0x800705BB

2019-11-19 23:11:18, Error MOUPG CSetupManager::Execute(284): Result = 0x800705BB

2019-11-19 23:11:18, Error MOUPG CSetupHost::Execute(420): Result = 0x800705BB

2019-11-19 23:13:42, Error CSI 00000001 (F) STATUS_OBJECT_NAME_NOT_FOUND #70# from Windows::Rtl::SystemImplementation:Upgrade from Windows 10 1809 to 1909 repeatedly fails due to Error 0xC1900101 – 0x20017 :DirectRegistryProvider::SysQueryValueKey(flags = 0, key = af4 (‘REGISTRYMACHINESOFTWAREMicrosoftWindows NTCurrentVersionFonts’), vn = [l:21 ml:22]’Arial Nova (TrueType)’, kvic = 2, kvi = 2, disp = 0)[gle=0xd0000034]

2019-11-19 23:13:42, Error CSI 00000002 (F) STATUS_OBJECT_NAME_NOT_FOUND #69# from Windows::Rtl::SystemImplementation::CKey::QueryValue(flags = 0, kn = [l:69]’RegistryMachineSOFTWAREMicrosoftWindows NTCurrentVersionFonts’, vn = [l:21 ml:22]’Arial Nova (TrueType)’, ic = KeyValuePartialInformation, data = {l:0 b:}, disp = 0)[gle=0xd0000034]

2019-11-19 23:14:51, Error DU DU::CDUSession::Search: Failed to set WU interior configuration assets for focused scans. hr = 0x80070057

2019-11-19 23:15:38, Error CONX 0xd0000034 Failed so as to add consumer mode driving force [%SystemRoot%system32DRIVERSUMDFuicciso.dll]

2019-11-19 23:22:31, Error SP pSPRemoveUpgradeRegTree: didn’t delete reg tree HKLMSYSTEMSetupUpgrade[gle=0x00000005]

2019-11-19 23:24:40, Error [0x080831] MIG CSIAgent: Invalid xml layout: FormatException: Component with show identify: Plugin/{C939EC0F-2F56-4CE8-AF56-2336596A5FA7} already loaded __cdecl Mig::CMXEMigrationXml::CMXEMigrationXml(elegance Mig::CPlatform *,elegance UnBCL::String *,elegance UnBCL::XmlDocument *,elegance UnBCL::String *,elegance UnBCL::String *)

2019-11-19 23:27:16, Error [0x080813] MIG CRegProcessingUnit:Upgrade from Windows 10 1809 to 1909 repeatedly fails due to Error 0xC1900101 – 0x20017 :processGather: Failed to get dataunit in POV enumeration for location(“HKLMSoftwareClassesInstallerAssembliesC:|Program Files (x86)|Microsoft Silverlight|5.1.50905.0|ar|Microsoft.VisualBasic.assets.dll [Micros]”)[gle=0x00000003]

2019-11-19 23:28:37, Error CSetupAutomation::Resurrect: File no longer discovered: C:$WINDOWS.~BTSourcesPantherautomation.dat[gle=0x00000002]

2019-11-19 23:28:37, Error SP CSetupPlatform::ResurrectAutomation: Failed to resurrect automation: 0x80070002[gle=0x00000002]

2019-11-19 23:31:04, Error MOUPG Finalize: Error acquiring Update and Shutdown Key: [0x80070002][gle=0x000000b7]

2019-11-19 23:31:16, Error SP CFinalizeCriticalBoundary:Upgrade from Windows 10 1809 to 1909 repeatedly fails due to Error 0xC1900101 – 0x20017 :DoExecute: Cannot create hardlink betweeen C:$WINDOWS.~BTSourcesUNBCL.DLL and C:WINDOWSSystem32OOBESetupPlatformUNBCL.DLL. Error: 0x80070050[gle=0x00000050]

2019-11-19 23:31:16, Error SP CFinalizeCriticalBoundary:Upgrade from Windows 10 1809 to 1909 repeatedly fails due to Error 0xC1900101 – 0x20017 :DoExecute: Rollback in machine context might not be registered.[gle=0x00000050]

🙂